16
Carefully replace the tube by pushing it in
deep enough (about 3 cm): Align the 2 holes
already drilled.
For Confort
, in order to adjust the length of the wires of the pH probe and temperature probe,
TM
proceed as follows:
18
Loosen the left-hand cable gland to release
the temperature probe. Adjust the length of
the wire so that the end of the probe is just
above the rigid tube plug.
The two cable glands must imperatively be properly retightened to ensure proper
operation of the device. Perform these operations with care, without pulling too
much on the wires.
20
Cut the black tube flush with the rigid tube,
using shears or heavy-duty scissors.
17
Tighten the 2 screws holding the tube, and
for Confort
TM
, put the pH probe back in its
housing behind the rigid tube.
19
Loosen the right-hand cable gland to release the
pH probe. Adjust the length of the wire so that
the end of the probe is immersed by 3 to 5 cm.
21
Replace the wedge plug.