Put the cover back on.
When your device switches out of TEST mode (specific tune), the siren of your immersion
detector will sound at full volume. The TEST mode can be reactivated for another
30 minutes: to do this, please refer to item 4.5.
3.7. Validation tests
Make sure that the pool is still, and that your immersion detector is monitoring (indicator light off).
If such is not the case, move the magnet over the swimmer symbol.
If in spite of this, your immersion detector does not switch to monitoring mode, this means that
the pool is not still enough. You must imperatively wait until your pool is still before carrying out
the tests.
1
Your immersion detector
is monitoring (indicator light off).
3
10 mn
Filtering and filtering robot
working for 10 minutes, your immersion
detector is monitoring (indicator light off)
and must not go off.
30
Tighten the 4 screws.
2
10 mn
Filtering working for 10 minutes,
your immersion detector is monitoring
(indicator light off) and must not go off.
4
With the filtering system and robot cleaner
working, drop the 6 kg weight from the point
furthest away from your immersion detector.
15