4.5. TEST mode

In this mode, the siren sounds only for a short time, and at a low volume. This mode allows you to
perform the installation and monthly tests without disturbing you or the neighborhood.
The TEST mode lasts for 30 minutes. Exit from the TEST mode is indicated by a 5-second,
low-volume specific tune.
When all tests have been carried out successfully, you must wait for 30 minimum minutes without
prompting the device to leave the test mode automatically.
If the device leaves the test mode before completion of the tests, disconnect the battery and wait
for a few minutes before reconnecting it to return to the test mode.
4.6. Off stop
In complete stop mode, the indicator light of your immersion detector flashes once per minute.
You are reminded that the French act No. 2003-9 dated 3 January 2003 on swimming pool safety
requires that a device be installed permanently throughout the year.
Your retailer or AstralPool, or MG International cannot be held liable in the event of drowning after
the removal or complete stopping of your alarm system for whatever reason.
When your immersion detector is in complete stop mode, vigilance by a person must
imperatively take over, or another standard safety system must be installed as an alter-
native.
To reactivate your immersion detector:
Move the magnet over the swimmer symbol;
I
I
You will hear 10 short, high-pitched beeps + flashing red indicator light;
Wait for the automatic restart (long beep - indicator light off) or restart manually (see item 4.3).
I
Please make sure that your immersion detector is in monitoring mode before leaving
your pool. If such is not the case, utmost vigilance is required from the parent/responsible
adult.
Place and keep one of the magnets on the red
stop sign until you obtain a continuous red light
signal, then move the second magnet over the
swimmer symbol.
A series of high-pitched beeps (10 short beeps)
and the indicator light flashing once a minute
confirm that the device is in complete stop mode.