Quick start programming

1.
Remove the cover of the electronics.
2.
Use the Down (
next.
3.
Press the Enter (
exclamation point (!).
4.
Use the Up or Down arrow keys
or to scroll through the choices.
5.
Press Enter
process (the default password is 0).
6.
To return to RUN mode, scroll to the display parameters (*Status*)
7.
After entering the last value, allow 10 seconds before removing power from the
transmitter (save function).
Password protection (Default = 0)
The SITRANS LG200 transmitter is password protected to restrict access to parts of the menu
structure that affect the operation of the system. In Program Mode, when the proper password
is entered, an exclamation point (!) is the last character of the first line of the display. The
password can be changed to any numerical value up to 255. The password is required
whenever configuration values are changed.
The default user password is 0. Enter a new password in the last step of the configuration
menu. With a password of 0, the transmitter is no longer password protected and any value in
the menu can be altered without entering a confirming password, except diagnostic values.
The device remains unprotected for five minutes without a button pressed, and then the
password protection set is applied.
If the user password is not known, the menu item New Password displays an
NOTE:
encrypted value representing the present password. Call the factory with this
encrypted value to determine the current password.
Activating SITRANS LG200
Power up the LG200. It begins in RUN mode and the display shows one of four read-only
values every 2 seconds: Status, Level, %Output, and Loop Current.

Accessing a parameter

1.
Use the ARROW keys
parameter. Hold the Arrow keys for rapid scrolling.
2.
Press Enter
3.
Use the ARROW keys
parameter value.
4.
Press Enter
next step of programming
5.
The LCD displays the new parameter and value.
7ML19985XG81
) arrow key to move from one step of the configuration program to the
) key. The last character in the first line of the display changes to an
to accept a value and move to the next step of the configuration
to scroll to an editable
to select a parameter.
to choose the
to accept a value and move to the
SITRANS LG200 – QUICK START MANUAL
to increase or decrease the value in the display
enter
down
up
Page EN-7