2. Test the exhalation
valve, take a deep
breath and hold it.
Block the inlet
connection with the
palm of your hand and
exhale. If the exhalation
valve is stuck, you may
feel a heavy rush of air
around the facepiece.
Note: You may need to exhale sharply to open the valve.
If this does not release the valve, do not use the
facepiece.
This device may not seal properly with your face if you
have a beard, gross sideburns or similar physical
characteristics (see ANSI Z88.2). An improper facial
seal may allow contaminants to leak into the
facepiece, reducing or eliminating respiratory
protection. Do not use this device if such conditions
exist. The face-to-facepiece seal must be tested
before each use. Never remove the facepiece except
in a safe, non-hazardous non-toxic atmosphere.
Failure to follow this warning can result in serious
personal injury or death.
TAL 1211 (L) Rev. 4 - 10088650
DONNING
Advantage 4000 Facepiece
Ultra Elite Facepiece
Advantage 4000 Facepiece
3. Open the cylinder valve
fully.
INSTALLING PUSH-TO-CONNECT MASK MOUNTED
REGULATOR
1. Grasp regulator and
orient regulator so that
red bypass knob is
pointing to the right.
2. Insert regulator into
facepiece adapter by
pushing inward.
3. Ensure the regulator locks into the facepiece.
4. Check proper engagement by pulling on the regulator
to ensure regulator is securely attached to facepiece.
Do not use the respirator unless the regulator is
connected properly. A regulator that is not installed
correctly can separate from the facepiece unexpectedly.
Return the respirator to an MSA trained or certified
repairperson to correct the condition. Failure to follow
this warning can result in serious personal injury or
death.
5. Inhale sharply to start the airflow.
a. Check the bypass again by turning the red knob
counter-clockwise until you feel increased airflow.
Close the bypass.