5.4 Establishing a Bluetooth connection

Note
If you are connecting the range meter to another device via Bluetooth for the first time, ensure that
Bluetooth is activated on the other device and that the counterpart device is set to be visible to other
devices. Without taking these two steps, it may not be possible to connect the range meter to the
other device.
1. Open the tool settings on the start page.
2. Switch on the "Bluetooth" option in the "WIRELESS & NETWORKS" section.
3. Select "More...".
◁ The tool searches for suitable Bluetooth devices.
4. In the settings on the device to which you want to connect the tool, ensure that the device is visible to
other devices and that it is able to connect to new devices. Further information may be included in the
documentation for the respective devices.
5. If no Bluetooth devices were found, select "Search for devices".
6. Select the device you wish to pair with under "Available devices" as soon as it is displayed.
7. Confirm the pairing by pressing "Yes" or "Pair".
Note
You can increase the battery life of the Li-ion battery if you deactivate Bluetooth after carrying out
a data transfer.

5.5 Settings for the measuring application

Setting
'Length unit'
'Slope unit'
'Audible signal'
'Vibration'
'Adjusting the inclination sen-
sor'
'Target picture'
Standard setting for the aiming
camera for direct measurement
('Target picture in direct mea-
surement')
Standard setting for the aiming
camera for combined functions
('Target picture in indirect
measurement')
'Default settings'
56
Description
Selecting the unit of length for distance measurement
For Japan: Tools registered in Japan are only able to work with
metric units.
Note
After selecting a different unit, any saved measurements are con-
verted into the new unit.
Selecting the unit of length for inclines
Switching the audible signal on or off
Switching the vibration on or off
Starting the adjustment process
Switching the creation of a target picture on or off. The target picture
is saved and displayed together with the measurement in the results
list.
Standard setting: On
Switch the use of the aiming camera on or off as the default setting
for direct measurements (individual measurements). In the "Off"
setting, the aiming camera can be switched on as needed. In the
"On" setting, the aiming camera is always switched on automatically
if a direct measurement is being prepared.
Standard setting: Off
Switch the use of the aiming camera on or off as the default setting
for all measurements except direct measurements. In the "Off"
setting, the aiming camera can be switched on as needed to simplify
positioning the laser spot. In the "On" setting, the aiming camera
is always switched on automatically if a measurement is being
prepared.
Standard setting: Off
The "On" setting reactivates the standard settings for all measuring
application settings.