Setup Soft Switches - Mettler Toledo VIVA Manual De Operación

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

METTLER TOLEDO

Setup Soft Switches

* PCS - price computing version, WO - weigh only version.
Group.Step
Group 1
1.3
Beeper
1.5
Decimal point
1.7
Auto-clear of Tare
Group 2
2.4
Digital Filter Selection
Group 3
3.1
Baud rate
3.2
Parity
3.3
Data
3.4
Bit stop
3.5
Chose Protocol
SAVE
Save or abort setting
** When selecting the 8217 Protocol, press the enter key several times until "Save" appears. This will setup the
scale for the default 8217 protocol. For customizing the 8217 protocol, please refer to the service manual.
VIVA Operation Manual
Function
ON - Scale will "beep" when a key is pressed.
OFF - No sound is made when a key is pressed.
ON - ,
OFF - .
ON – Tare is automatically cleared when weight is removed.
OFF – Tare is not cleared when weight is removed.
0 - Minimal
1 - Low
2 - Medium
3 – High
0 = 1200
1 = 2400
2 = 4800
3 = 9600
0 = None
1 = Even
2 = Odd
0 = 7 data bit
1 = 8 data bit
0 = None
1 = 1 stop bit
2 = 2 stop bit
PCS Only
0 = IP3 Testut
1 = L2 Mettler-Toledo
2 = Berkel
3 = Anker
4 = Dialog 02/04
5 = Dialog 06
WO Only
6 = 8217 Mettler Toledo**
7 = Berkel
8 = NCI Weightronix
9 = Epelsa
SAVE = save all setting and return to weighing mode
ABORT = abort all setting and return to weighing mode
Possible Selections
13

Publicidad

Capítulos

Tabla de contenido
loading

Este manual también es adecuado para:

Rn20

Tabla de contenido