Process display
Mechanical
Dimansions
construction
Weight
Materials
Electrical
connection
Display and
Display
operation level
Display range
Offset
Operation
Interface
Set point
Mode
function
Number
Display
Scan rate
Power supply
Power supply
Power
consumption
Fuse
Certification
CE mark
GL-Marine
approval
UL
CSA GP
Technical alterations reserved!
76
H: 48 mm, W: 96 mm, D: 150 mm
600 g
Housing front: Die cast aluminium
Housing casing: Galvanised sheet steel
Housing rear panel: Plastic ABS
Plug on scew terminals, size 1.5 mm² solid, 1.0 mm²
multi core with ferrule
LED display, 2 colour
numeric display: 5 x 7 segment
(red or green, 13 mm)
Bargraph display: 12 element (yellow)
Set point infringement: 4 x 1 segment (yellow)
-19999 to +99999
-19999 to +99999
3 push button operation (-/+/E) and/or software
RS232, on the rear panel, 3.5 mm stereo socket
Off, minimum, maximum safety, alarm
2
2 LED per set point
1s
90 to 250 V
, 50/60 Hz
AC
18 to 36 V
, 20 to 28 V
DC
11.5 VA (90...250 V AC)
5.5 VA (18...36 V DC; 20...28 V AC)
315 mA slow blow (90 to 250 V
1 A slow blow (18 to 36 V
Directives 89/336/EWG and 73/23/EWG
Germanische Lloyd / marine approval
Recognized component to UL 3111-1
CSA General Purpose
, 50/60 Hz
AC
),
AC
)
DC