F50E
- Remove the rear panel by unfastening the fixing screws.
- Disconnect the thermostat fastons (item 7 plate. A)
- Replace the remote control switch, disconnecting it from the omega
bar
- Perform the above operations in reverse order to reassemble.
F60E-F80E
- Unfasten the two front fixing screws (Item 2 Fig.20) and extract the
whole electric panel (Item 1 Fig.20), sliding it forwards on its guide;
- Disconnect the remote control switch terminals;
- Replace the remote control switch, disconnecting it from the omega
bar (item 7 plate A);
- Perform the above operations in reverse order to reassemble.
5.3.6
REPLACING THE LOW-VOLTAGE TRANSFORMER
After carrying out the operations described in 5.1 above, to replace the
low voltage transformer proceed as follows:
F50E
- Remove the rear panel by unfastening the fixing screws
- Disconnect the transformer fastons (item 2 plate A)
- Unfasten the fixing screws
- Perform the above operations in reverse order to reassemble.
F60E-F80E
- Unfasten the two front fixing screws (Item 2 Fig.20) and extract the
whole electric panel (Item 1 Fig.20), sliding it forwards on its guide;
- Disconnect transformer terminals (item 2 plate A)
- Unfasten the fixing screw and replace the transformer;
- Perform the above operations in reverse order to reassemble.
5.3.7
REPLACING THE 12V RELAY
After carrying out the operations described in 5.1 above, to replace the
relay proceed as follows:
F50E
- Remove the rear panel by unfastening the fixing screws
- Remove the relay (item 6 plate A) from the base
- Perform the above operations in reverse order to reassemble.
F60E-F80E
- Unfasten the two front fixing screws (Item 2 Fig.20) and extract the
whole electric panel (Item 1 Fig.20), sliding it forwards on its guide;
- Remove the relay (item 6 plate A) from the base and replace it;
- Perform the above operations in reverse order to reassemble.
5.3.8
CHANGING THE PYROMETER
After carrying out the operations described in 5.1 above, to replace the
pyrometer proceed as follows:
F50E
- Remove the front control panel by unfastening the fixing screws;
- Remove the casing on the digital pyrometer and the corner fastenings;
- Disconnect the thermostat faston connectors;
- Replace the pyrometer (item 9 plate A );
- Perform the above operations in reverse order to reassemble, taking
care that the connectors are inserted in the correct poles.
F60E-F80E
- Unfasten the two front fixing screws (Item 2 Fig.20) and extract the
whole electric panel (Item 1 Fig.20), sliding it forwards on its guide;
- Take off the nuts and remove the pyrometer (item 9 plate A );
- Disconnect the pyrometer electrical connectors;
- Replace the pyrometer;
- Perform the above operations in reverse order to reassemble, taking
care that the connectors are inserted in the correct poles.
5.3.9
CHANGING THE LAMPS
After carrying out the operations described in 5.1 above, to replace the
lamps proceed as follows:
- Open the door.
- Turn the two screws (Fig. 21 Item A) fixing the glass by a ¼ turn.
- Gently open the glass panel hinged to the door, making it possible to
access the inner part;
- Remove the old lamps (item 27 plate A);
- Replace the lamps with others of the same voltage and power;
- Perform the above operations in reverse order to reassemble.
5.3.10
REPLACING THE MAIN SWITCH
After carrying out the operations described in 5.1 above, to replace the
main switch proceed as follows:
F50E
- Remove the front control panel by unfastening the fixing screws;
- Take off the casing on the rear of the control panel;
- Disconnect the switch faston connectors;
- Replace the switch (item 4 plate A );
- Perform the above operations in reverse order to reassemble.
F60E-F80E
- Unfasten the two front fixing screws (Item 2 Fig.20) and take out the
whole electric panel (Item 1 Fig.20), sliding it forwards on its guide;
- Disconnect the main switch faston connectors (item 4 plate A );
- Replace the main switch;
- Perform the above operations in reverse order to reassemble.
5.3.11
REPLACING THE CYCLICAL PROGRAMMER WITH
MOTOR (F50E only)
After carrying out the operations described in 5.1 above, to replace the
cyclical programmer with motor proceed as follows:
- Remove the rear panel by unfastening the fixing screws
- Disconnect the wiring from the programmer (items 22, 23 plate A)
- Unfasten the fixing screws
- Perform the above operations in reverse order to reassemble.
5.3.12 OPENING THE INNER GLASS DOOR
After carrying out the operations described in point 5.1 above:
- Open the door
- Turn the two screws fastening the glass (Item A - Fig.21) by ¼ turn
- Gently open the glass that is hinged to the door, so that it is possible
to access the internal part
- Refit by following these steps in reverse order.
- If the baking chamber glass is replaced, the new glass must be fitted
with the smooth side facing the inside of the chamber.
- On the F50E, take care to make sure that the centre of the recess is
level with the centre of the handle
5.4
REPLACING
COMPARTMENT
5.4.1
REPLACING THE LIGHT BULB
After carrying out the operations described in 5.1 above, to replace the
light bulb and/or cover, from the inside of the leavening
compartment,proceed as follows:
- Unscrew the cover (item 16 plate B) and replace the bulb (item 8 plate
B) and/or the cover itself;
- Refasten the cover.
5.4.2
CHANGING THE BALL KNOB (F50L only)
After carrying out the operations described in 5.1 above, to replace the
ball knob proceed as follows:
- Open the doors of the leavening compartment;
- Remove the cap;
- Unscrew the fixing nut inside the knob;
- Replace the knob (item 2 plate B) and tighten the fixing nut;
- Perform the above operations in reverse order to reassemble.
5.4.3
REPLACING THE THERMOSTAT DIAL AND BEZEL
(F50L only)
After carrying out the operations described in 5.1 above, to replace the
thermostat dial and/or relative bezel, proceed as follows from the outside
of the compartment:
- Remove the snap-on thermostat dial (item 5 plate B).
- Unscrew the fixing bezel (item 6 plate B);
- Replace the bezel and/or the dial.
5.4.4
REPLACING THE THERMOSTAT DIAL (F50L UM –
F60/80L UM)
After carrying out the operations described in 5.1, to replace the
thermostat dial proceed as follows from the outside of the compartment:
- Remove the snap-on thermostat dial (item 5 plate B);
- Replace the dial.
5.4.5
THERMOSTAT REPLACEMENT
After carrying out the operations described in 5.1 above, to replace the
safety thermostat proceed as follows:
- Remove the control panel fixing screws;
- Disconnect the thermostat faston connectors.
UK/8
PARTS
OF
THE
LEAVENING