Motor current monitoring

14 Motor current monitoring
Designation
Motor current monitoring

14.1 Exploded view

Fig. 26
1
BCD switch

14.2 Function

This function monitors the motor current. If the motor current is greater than the
preset value, a malfunction is reported.
Switch position
0
1
2
3
4
5
6
7
8
9

14.3 Setting values

 When setting the BCD switches, make sure that the set functions do not block one
another.
Example:
EA21: BCD1 cycle time level 3 = 19s
BCD 2 cycle time monitoring level 0 = 7s
86
Technical data
2
Max. motor current / mA
200
400
600
800
1,000
1,200
1,400
1,600
1,800
2,000
Accessories for electrical actuators
Code
199 190 081
LED
Delivery position EA21
Delivery position EA31
Delivery position EA42