6. Hold impeller fi rmly against the suction bowl/bell
and drive the taperlock into place with a taperlock
driver, (See Figure 14). After the impeller is secured
in position, the top end of the taperlock should be
1/8" above the impeller hub.
TAPERLOCK
DRIVER
DISASSEMBLY
POSITION
Figure 14
7. Slide intermediate bowl (670) onto shaft and secure
with capscrews provided.
8. Repeat preceding procedure for number of stages
required.
9. Remove long capscrew and the assembly jig at the
end of suction hub and check that the shaft rotates
freely without dragging or binding. Also check for
adequate lateral (end play).
FINAL ASSEMBLY
After assembly of bowl assembly, reassemble pump
as described in "Installation" and also "Startup and
Operation Procedures".
Repair Parts
Repair Parts
ORDERING PARTS
When ordering spare or replacement parts, the pump
serial number, size and type of pump must be given. This
SHAFT
can be found on the nameplate furnished with the unit.
Give the complete name and reference number of each
part as indicated on the applicable sectional drawings,
Figure 1 or Figure 2, and the quantity required.
STOCKING SPARE PARTS
Spare parts to be kept in inventory will vary according
to service, fi eld maintenance, allowable down time and
number of units. A minimum inventory of one complete
set of bearings and one spare of each moving part is
suggested.
IMPELLER
RETURNING PARTS
A completed Return Material Authorization (RMA) form
must accompany all materials returned to the factory.
The RMA forms can be obtained direct form the factory
or through your local Goulds representative. The RMA
BOWL
form must be fi lled in completely and forwarded as
directed thereon. Parts being returned under warranty
claim must have a complete written report submitted
with the RMA form.
CAUTION
factory cannot assume any responsibility for parts
damaged in transit.
Returned material must be carefully
packaged to prevent transit damage - the
25