Clearing The Remote Controls And All Settings; Clearing All Remote Controls; Clearing All Motorisation Settings; Diagnostics - SOMFY Elixo 500 24 V Manual De Instalación

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Elixo 500 24 V
Menu [Display]
START-CLOSE selection
[StArt - cLoSE]
Pedestrian opening
[PEdEStrIAn]
Preset [dEFAULt]: to reset the motor (factory default settings).

CLEARING THE REMOTE CONTROLS AND ALL SETTINGS

Clearing all remote controls

Press the PROG button on the motorisation control unit for more than 7 seconds. The indicator light fl ashes to indicate that all
remote controls have been cleared.
Clearing all settings
[1]
Press OK twice to access the menus.
[2]
Use the + and - buttons to access the
[3]
Press OK to clear all settings.
The Elixo motorisation has been reset and returns to its original confi guration (factory default
settings).
Before using the motorisation, carry out a new self-learning procedure (see pg. 8).

DIAGNOSTICS

Meaning of messages displayed on the screen

Before accessing the menu list, the control unit screen displays the following information:
Somfy,
Control unit software version,
Number of cycles carried out (expressed in hundreds; during the fi rst 100 manoeuvres the screen displays 0000).
Whilst the motorisation is in use, messages are displayed to show the system's status.
In the event of incorrect operation, a message will be permanently displayed to show the device to be checked. If the problem is
not corrected or if it persists, please contact Somfy technical assistance.
Message
Meaning
OK
Self-learning successful
KO
Self-learning unsuccessful
Awaiting input of a value or function
End
Exit programming mode
SuC
Closing end limit activated
SuO
Opening end limit activated
AMP
Obstacle detected
PED
Pedestrian entry activated
STRT
START entry activated
STOP
STOP entry activated
PHOT
PHOT entry activated
CLOSE
CLOSE entry activated
OPEN
OPEN entry activated
SWO
Opening end limit entry activated
SWC
Closing end limit entry activated
TH
Software thermal protection activated
12
Value
ON: the input between
terminals 21 and 22 operates
as CLOSE.
OFF: the input between
terminals 21 and 22
operates as START.
ON: Activates the pedestrian
opening.
OFF: Deactivates the
pedestrian opening.
menu.
dEFAULt
Permanent display
Check that the device controlling pedestrian entry is operating correctly (keyswitch,
wired keypad, etc.)
Check that the device controlling the START entry is operating correctly.
Check that the device controlling the STOP entry is operating correctly.
Check that nothing is obstructing the photoelectric cells.
Check that the photoelectric cells are not dirty (see guide for the cells).
Check that the device controlling the CLOSE entry is operating correctly.
Check that the device controlling the OPEN entry is operating correctly.
Faulty electro-magnetic detection system. Replace it.
Faulty electromagnetic detection system. Replace it.
Wait until the message disappears before continuing to use the motorisation.
By
Comments
default
OFF
CLOSE: the device connected between terminals 21 and 22 only
enables the gate to be closed.
START: the device connected between terminals 21 and 22
enables the motorisation to operate in sequential mode.
OFF
Operation of the pedestrian opening: pressing the button briefl y
opens the gate partially and pressing and holding the button opens
the gate fully.
Fixed opening time: 7 seconds.
OK
OK
- +
OK
OK
+ -