4.11 Display P; 4.12 Ar Key - Wire Test; 4.13 Aq Key - Test Gas - Cebora 208-10 Manual De Istrucciones

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

CEBORA S.p.A.

4.11 Display P.

In every welding process, with led J lit, displays the value of the welding voltage expressed in Volt.
With led J off, temporarily (5 seconds) displays the "Arc Length Correction", expressed in a number
between -9.9 and 9.9, default = 0;
In some cases it shows part of a message completed by the display O:
in Job mode, it temporarily (5 seconds) displays the number of the selected Job. If the selected "Job
number" does not correspond to an existing Job, the message on display P flashes.
in Standard Program mode, Pulsed Arc Program mode and Manual mode, if the selected
"program number" does not correspond to an existing program it displays PrG (complete abbreviation
no PrG);
in the event of an error message of the Power Source, it displays the error number. Display O shows
the abbreviation Err;
in the "Service Functions" menù displays the possible choices in response to the function shown on
display O;
in the "Second Functions" menù displays the possible choices in response to the function shown on
display O.

4.12 AR key - Wire test.

Always operative.
GB
Causes the wire to move forward with an initial speed of 0.7 m/min, which after 5 s increases up to 8
m/min, in approximately 0.7 s.
Everything takes place without generating the output voltage to the Power Source and without gas output
from the torch.

4.13 AQ key - Test gas.

Always operative.
Causes gas to be emitted from the torch.
Has "bistable" operation: the first time it is pressed causes gas to be emitted, while pressing it a second
time interrupts the flow.
If the second pressure does not takes place and welding does not begin, gas output is automatically
interrupted after 30 seconds.
3.300.189-B
32
04/03/2016

Publicidad

Tabla de contenido
loading

Tabla de contenido