CEBORA S.p.A.
7.4
Automatic Hot Start (HSA).
Press for a time longer than 3 seconds the key E to enter the "Second Functions" menù.
Use knob N to select HSA on display O; with knob Q select the function status, visible on display P:
OFF = not active (default);
On
= active.
With the HSA function active, other parameters become available, selectable with knob N:
SC on display O ("hot-start" current level); use knob Q to assign a value to the field SC, visible on
display P. Regulation range: 10 ÷ 200 s, default = 135;
tSC on display O ("hot-start" current lasting time); use knob Q to assign a value to the field tSC,
visible on display P. Regulation range: 0.1 ÷ 10.0 s, default = 0.5;
SLo on display O (time for switching between "hot-start" current and welding current); use knob Q to
assign a value to the field tSC, visible on display P. Regulation range: 0.1 ÷ 10.0 s, default = 0.5.
Press briefly the key E to exit the "Second Functions" menù, saving all current settings automatically.
7.5
Crater Arc (CrA).
Available starting with the firmware in release 6 for art. 287 and 13 for art. 289.
Press for a time longer than 3 seconds the key E to enter the "Second Functions" menù.
Use knob N to select CrA on display O; with knob Q select the function status, visible on display P:
OFF = not active (default);
On
= active.
With the CrA function active, other parameters become available, selectable with knob N:
Slo on display O (time for switching between welding current and crater current); use knob Q to
assign a value to the field Slo, visible on display P. Regulation range: 0.1 ÷ 10.0 s, default = 0.5;
CrC on display O (percentage of wire speed during welding, corresponding to welding current); use
knob Q to assign a value to field CrC, visible on display P. Regulation range: 100 ÷ 200 % of wire
speed set for welding, default = 60%;
tCr on display O (duration of the crater current); use knob Q to assign a value to the field tCr, visible
on display P. Regulation range: 0.1 ÷ 10.0 s, default = 0.5.
Press briefly the key E to exit the "Second Functions" menù, saving all current settings automatically.
7.6
Pre Flow (PrF).
Press for a time longer than 3 seconds the key E to enter the "Second Functions" menù.
Use knob N to select PrF on display O; with knob Q select the duration time of the Gas Pre Flow, visible
on display P (indication expressed in seconds).
Regulation range: 0 ÷ 10 s, default = 0.1.
Press briefly the key E to exit the "Second Functions" menù, saving all current settings automatically.
7.7
Post Flow (PoF).
Press for a time longer than 3 seconds the key E to enter the "Second Functions" menù.
Use knob N to select PoF on display O; with knob Q select the duration time of the Gas Post Flow,
visible on display P (indication expressed in seconds).
Regulation range: 0 ÷ 25 s, default = 3.
Press briefly the key E to exit the "Second Functions" menù, saving all current settings automatically.