5.3.4
Burn-Back Time Correction.
Set the wire length exiting the torch nozzle after welding, expressed as a time interval (milliseconds).
The Burn-Back Time Correction adjustment is enabled or disabled by means the Burn-Back Time
Correction Disable function, available on RAI211 and RDI210 Robot Interfaces.
The corresponding bit is controlable with dip switch S1-4 on RAI211 Robot Interface or with the signal
"I100" of the Data-In Process Image on RDI210 Robot Interface (see Robot Interface Instruction
Manual):
- with "Burn-Back Time Correction Disable" not active (S1-4 = OFF, or I100 = low) the "Burn-
Back Time Correction" adjustment is enabled in Standard program, Pulsed arc program and
Manual modes, and follows the value set at Robot Interface analog input 4. The adjustment is carried
out via Robot Terminal;
- with "Burn-Back Time Correction Disable" active (S1-4 = ON, or I100 = high) the "Burn-back
Time Correction" is not active.
Independently from the Burn-Back Time Correction Disable function state, in Parameter Selection
Internal mode, is always possible to adjust the Burn-Back Time Correction from Control Panel (par.
7.9).
Correction regulation range: -125 ÷ +125 ms.
The Burn-Back Time effective value after the correction is always comprised between 4 ms. and 250 ms.
When the correction set up is equal to 0 the Burn-Back Time parameter is set to its default value,
indicated with Au (automatic).