Recirculating through
A
G
I
C
B
D
F
H
A. Ceiling
B. Recirculating grid
C. Soffit
D. 6" round vent system
E. Range hood
NOTE: 12" (30.5 cm) high cabinets without a soffit may allow the
6" vent and vent cover to be seen.
8. Measure and mark the centerline of the cabinet top wall or
the soffit above.
9. Measure from the bottom of the cabinet to the centerline of
the where the vent will come through the cabinet top wall or
the soffit. Mark the location and use a saber saw or keyhole
saw to cut a 5¾" (14.6 cm) hole for the vent cover.
10. Cover the grill that protects the suction motor with the carbon
filter so that the slots on the filter correspond to the pins on
the sides of the motor protection grill.
11. Turn the carbon filter clockwise to block them (bayonet fixing).
NOTE: The charcoal filters cannot be cleaned. It should be
replaced every 4-6 months (depending on hood usage).
the soffit
E
F. Cabinet
G.Wall
H. 12" (30.5 cm) min. cabinet height
I. 3
⁄
"x10" rect. to 6" round converter
1
4
Electrical Connection
WARNING: Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
1. Remove the knockout and the Junction box cover and install
the conduit connector (cULus listed) in junction box.
A
B
C
D
A. White wires
B. Black wires
C. UL listed wire connector
2. Run 3 wires; black, white and green, according to the National
Electrical Code and local codes and ordinances, in
conduit form service panel to junction box.
WARNING: Electrical Shock Hazard
Electrically ground blower.
Connect ground wire to green and yellow ground wire in
terminal box. Failure to do so can result in death or electrical
shock.
3. Connect black wire from service panel to black or red in
junction box, white to white and green to green-yellow.
4. Close and secure junction box cover.
Finall installation step
•
Replace filters.
•
Check operation of the hood.
If range hood does not operate:
•
Check that the circuit breaker is not tripped or the house
fuse blown.
•
Disconnect power supply.
•
Check that wiring is correct.
Keep your Installation Instructions and Use and Care Guide close
to range hood for easy reference.
8
E
F
D. Green (or bare) and yellow-green ground wire
E. Home power supply cable
F. UL listed or CSA approved ½" strain relief
1
⁄
2
"