Electrical Connection - arietta ADI436SSB Guía De Instrucciones Para Instalación

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

11. Install the 4 vertical supports with 16 - 4.2x8 mm screws.
Check everything is tightly screwed.
A
B
A. 4 - Lower vertical supports
B. 16 - 4.2x8 mm screws

Electrical Connection

I
WARNING
ELECTRICAL SHOCK HAZARD.
I
WARNING
DISCONNECT POWER BEFORE SERVICING.
REPLACE ALL PARTS AND PANELS BEFORE OPERATING.
FAILURE TO DO SO CAN RESULT IN DEATH OR ELECTRICAL
SHOCK.
1. Disconnect power.
2. Remove terminal box cover.
3. Remove the knockout in the terminal box cover and install a
UL listed or CSA approved 1⁄
A. Terminal box
B. Knockout
C. Terminal box cover
4. Run home power supply cable through strain relief, into
terminal box.
" strain relief.
2
B
C
A
12. Remove the 2 leveling screws from the structure.
A
A. 2 - Leveling screws
G
A. Home power supply cable
B. UL listed or CSA approved strain relief
C. UL listed wire connectors
D. White wires
5. Use UL listed wire connectors and connect black wires (C)
together.
6. Use UL listed wire connectors and connect white wires (E)
together.
I
WARNING
ELECTRICAL SHOCK HAZARD.
I
WARNING
ELECTRICALLY GROUND BLOWER.
CONNECT GROUND WIRE TO GREEN AND YELLOW GROUND
WIRE IN TERMINAL BOX. FAILURE TO DO SO CAN RESULT IN
DEATH OR ELECTRICAL SHOCK.
7. Connect green (or bare) ground wire from home power supply
to yellow-green ground wire (F) in terminal box using UL listed
wire connectors.
8. Tighten strain relief screw.
9. Install terminal box cover.
10. Reconnect power.
8
A
A
B
C
D
E
F
E. Black wires
F. Green (or bare) and yellow-
green ground wires
G. Terminal box

Publicidad

Tabla de contenido
loading