Installing the range hood
1.
Using 2 or more people, hang range hood on 2 mounting
screws through the mounting slots on back of hood.
B
C
A. Mounting screws
B. Mounting slots
C. Lower mounting screws
2.
Mark with a pencil the lower mounting holes location.
3.
Uninstall the hood assembly, and drill
holes at marked locations.
4.
Hang the range hood again on 2 upper mounting screws.
5.
Level the range hood and tighten upper mounting screws.
6.
Install 2 - 5 x 45 mm lower mounting screws and tighten.
Use the optional wall anchors if needed.
Connect Vent System
1.
Install transition on top of hood (if removed for shipping) with
2 - 3.5 x 9.5 mm sheet metal screws.
A
B
A. Vent transition
B. 3.5 x 9.5 mm screw
For vented installations only:
2.
3.
A
4.
⁄
" (4.8 mm) pilot
5.
3
16
Electrical Connection
WARNING: Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
1.
2.
3.
4.
A. UL listed wire connectors
B.White wires
C. Black wires
5.
6.
WARNING: Electrical Shock Hazard
Electrically ground blower.
Connect ground wire to green and yellow ground wire in
terminal box. Failure to do so can result in death or electrical
shock.
6
Fit vent system over the exhaust outlet.
Measure from the bottom of the air deflector to the bottom
of the hood outlet. Cut the ductwork at the measured
dimension.
Roof
outlet
Wall
outlet
Seal connection with clamps.
Check that back draft dampers work properly.
Disconnect power.
Remove terminal box cover.
Remove the knockout in the terminal box cover and install
a UL listed or CSA approved
Run home power supply cable through strain relief, into
terminal box.
E
D
C
B
A
D. Green (or bare) wire connected to
E. Home power supply
Use UL listed wire connectors and connect black wires
(C) together.
Use UL listed wire connectors and connect white wires (B)
together.
Dimension
to measure
⁄
" strain relief.
1
2
yellow-green wires