EMCA-EC-67-...
4.2

Electrical data

Control ports STO 1/STO 2 [X6]
Nominal voltage
Voltage range
Permitted residual ripple
Overvoltage-safe up to
Nominal current
Starting current
Input voltage thresholds (Intermediate range is undefined.)
Deactivate STO
Activate STO
Activate STO function switching time
Deactivate STO function switching time
Max. permissible pulse width
for 0 V test pulse with 24 V signal
for 24 V test pulse with 0 V signal
Min. time between test pulses
for 0 V test pulse with 24 V signal
for 24 V test pulse with 0 V signal
Protective function
1) This value refers to a simple pulse. Double or multiple pulses can require other values.
2) Longer 0-V test pulses or double/multiple pulses of the safety switching device require an increase of the voltage level up to
the upper limit of the permissible voltage range of the EMCA.
Tab. 11
Technical data: Electrical data for the inputs STO 1 and STO 2
Acknowledgment contact NC [X6]
Design
Max. voltage
Overvoltage strength
Nominal current
Max. internal resistance (contact closed)
Residual current (contact open)
Switching time closing
Switching time opening
Galvanic isolation
Tab. 12
Technical data: Electrical data of the acknowledgment contact
Festo – EMCA-EC-67-... – 1603 English
[V DC] 24 (relative to 0 V at [X4] )
[V DC] 19.2 ... 28.8
[%]
5 (relative to nominal voltage 24 V)
[V]
60
[mA]
15
[mA]
200
[V DC]  18
[V DC]  5
 5
[ms]
 4
[ms]
1)2)
[ms]
0.6
[ms]
10
[ms]
60
[ms]
4
Protection against polarity reversal
Semiconductor relay
[V DC]  30
[V]
60
 100
[mA]
 40
[Ω]
 2
[μA]
 10
[ms]
 60
[ms]
Via optocoupler
39