EMCA-EC-67-...
4
Technical data
The general technical data, operating and ambient conditions, technical data of the drive
and additional connection data can be found in the description of the EMCA integrated
drive è Manual GDCE-EMCA-EC-...
For additional information è www.festo.com/sp.
4.1
Safety equipment
Safety reference data and safety specifications
Safety function
Category
Performance Level up to
Safety Integrity Level up to
SIL Claim Limit
DCavg
HFT
SFF
PFH
T
Proof Test Interval
Service life
Type test
Component/function
Tab. 10
Technical data: Safety reference data and safety specifications
38
STO
3
PL d
SIL 2
SIL CL 2
[%]
90
1
[%]
> 90
-9
[1/hr.]
1 x 10
[Years]
20
[Years]
20
The STO function has been certified by an independent test
ing body. EMCA certificate è www.festo.com/sp.
Suitable for use in category 1 systems and above in accord
ance with EN ISO 138491.
Safe Torque Off
(safely switched-off torque)
In accordance with EN ISO 13849-1
In accordance with EN ISO 13849-1
In accordance with EN 61800-5-2
(Safety integrity level)
In accordance with EN 62061
(SIL Claim Limit)
Average Diagnostic Coverage
è Chapter 1.1.3
Hardware Failure Tolerance
Safe failure fraction in accordance with
IEC 61508
Probability of dangerous failure per hour
Inspection interval
In accordance with EN ISO 13849-1
Festo – EMCA-EC-67-... – 1603 English