Once the lower plates have been removed, it is possible to remove the upper plates by pushing
the plate.
This last action will cause the plates to be released at the bottom and by letting them lower you
can remove them.
EN
In this way it is possible to check the entire smoke passage surface of the combustion chamber.
Using a vacuum cleaner and a steel brush, clean the entire combustion chamber.
For an effective cleaning you should develop it following this order: first heat exchanger in
casting, all the walls, the place of installation of the firing basket and the entire lower surface
of the combustion chamber.
Then remove the safety locks and remove the equipment to the outside of the pladur for easy
access.
The smoke extractor is located on the left side of the equipment. It's mainly composed of two
parts, the body and the motor.
To clean the extractor it is necessary to remove the cap with the motor, remove the screws
with a Phillips screwdriver PH2 (be careful not to injure the seal gasket – CO1206020000003
VFC1-120 extractor gasket). You can use a brush and a vacuum cleaner to remove any dirt
from the extractor walls and propellers.
To proceed with the cleaning, it is necessary to remove the equipment completely from the
guides (do not forget the procedure initially requested to disconnect the equipment from the
electrical power).
Then raise the device approximately 1 palm on the front so that the rails can be detached from
the fixed guide rails.
Afterwards and with the help of another person (weight of the equipment about 100 kg) remove
the equipment completely and place it on a stable horizontal surface that allows to receive the
weight of the equipment.
After the previous point it is possible to access the fixed part of the equipment.
The smoke box is located at the rear left of the equipment. The gasket between the
fume box and the extractor can be checked in this fume box. The condition of this red gasket
must be checked during maintenance. It must be free of cracks or cuts and must maintain its
elasticity (it must not be rigid). If it is not in good condition, it must be replaced
(CO0510000750000).
The smoke box referred to in the previous point has a side cover (right side from the front) fixed
with 6 DIN 912 M6x12 screws. It can be accessed using an Allen key 5.
After removing the screws and using an ash vacuum cleaner, clean all surfaces.
Inside the box there are two smoke deflectors, positioned as shown in Figure 52, to carry out a