Ventilation: for the optimal operation of the unit, the assembly site must have air inlet installed
with a minimum cross section of 100 cm², preferably at the back of the unit.
If the house is equipped with air exhaust system (e.g. kitchen extractor fan), a top ventilation
section must be installed, suitable to accommodate the different air exhaust systems existing
in the household.
EN
Installing the unit in locations near kitchen exhaust fans or fume extractors may prevent the
correct operation of the unit and, in certain situations, may cause the inversion of the chimney
draught flow which will expel the fumes into the room where the unit is installed.
Installing with a chimney
The installation of the pellet insert brings the exhaust pipe (∅ 80 mm) directly into the chimney.
If the chimney is too large, it is recommended to pipe the gas outlet
with a pipe with a minimum internal diameter of 80 mm.
Provide a "T" for the periodic inspections and the annual maintenance.
When atmospheric conditions are so adverse that they cause a significant disturbance in the
drawability of the insertable gases (in particular very strong winds), it is advisable not to use
the insert.
If the equipment is not used for an extended period of time, the user must ensure that there is
no blockage in the chimney tubes prior to lighting.
Installation view with chimney
EN // 92