Never touch the interior of the unit without disconnecting it from the power mains.
Do not place pellets directly in the firing basket, it may cause overloads that produce bad
combustion or risk of explosion.
EN
Minimum distances of all surfaces: top view of the installation of the equipment
0,01 m
0,01 m
Installing and fixing the pellet insert
Before you begin the installation, perform the following actions.
The recommended measures for installing the pellet insert are as follows:
Width:
695 mm
Height: 610 mm
Depth: 550 mm
The inserts have 1 finishing frame to cover bigger holes, giving greater versatility to the insert.
The frame is 44 mm wide to finish the equipment's installation.
The surface where the base of the equipment is to be fixed must be levelled and have the
necessary strength to support the entire weight of the equipment and its subsequent movements
to load pellets.
The base of the equipment has 7 holes to attach to the support.
As can be seen in Figure 8, a distance of 62,5 mm from the base to the front of the wall must
be left (it must be perfectly parallel).
The equipment has an approximate weight of 100 kg and when it is extracted to the pellet/
maintenance position, it exerts a high force on the base, during installation it is necessary to use
anchoring material suitable for the type of base, soil and wall (In the case of extending table).
EN // 95