INSTALATION

List of tools:
EN
PZ2 star wrench
Umbrako wrench 6 mm
Philips PH2 screwdriver
Installing ducts and fume extraction systems
The exhaust pipe must have been designed for and dedicated to this purpose, in compliance
with local requirements and any applicable regulations.
An inspection-T with an airtight lid must be attached to the exit of the unit's exhaust
pipe to allow for the regular inspection of the system or discharge of heavy dust and
condensates.
As shown, the exhaust duct should be assembled in a way that allows for the cleaning and
servicing using the insert of the inspection points.
Under normal operating conditions, the combustion gas exhaustion must create a draught of
12 Pa, one meter above the fume exit.
The unit must not share the chimney with other equipment.
The pipes installed outside the household must have double stainless-steel insulation and an
internal diameter of 80 mm.
The fume exhaust pipe may generate condensation, so we recommend that the appropriate
systems for collecting condensates are installed.
Installing without a chimney
The installation of this unit without a chimney must be made by bringing the fume exhaust
pipe (with minimum internal diameter of 80 mm) directly out and over the top of the roof at
approximately 0,5 m higher.
Double-walled stainless-steel insulated pipes must be used and properly attached to avoid
condensation.
A T-connection must be installed at the base of the pipe to allow for periodic inspections and
annual maintenance.
EN // 90