Push the movable part to the wall so that it slides on the rails. Check the correct sliding and that
everything is properly attached before continuing with the installation. Move the equipment to
the end of runner system with open safety latches and once in position, close them to ensure
that the equipment is properly placed in the working position.
Connect the power cord to a 230V 50Hz grounded outlet.
EN
After connecting the power cable to the silo column, it is necessary to attach the cable to the
same column and the base, making sure to leave enough cable length, so that the equipment
can make the entire route in the rails (500 mm), without the cable being stressed or touching
the hot parts.
Temperature probe installation
The pellet inserts have a probe to measure the ambient temperature. For a correct reading of
the ambient temperature, this probe must be located on the exterior in a place where it does
not receive direct radiation or hot air from the equipment. It is sufficient to drill a hole in the wall
and fix the box screwed or glued, leaving the end of the probe inside. Sufficient length of cable
must be left so that the moving part of the equipment can be removed without causing strain
on the cable and does not interfere with the movement of the equipment guides.
Auxiliary table installation
To perform a root installation. A height adjustable table is available to facilitate the installation
of the equipment. The table is adjustable in height and has 2 components to regulate the depth
and be able to fix it to the back wall. It also has holes in the lower legs to facilitate fixation to
the floor.
It is very important that the table is levelled, both in depth and width, this will facilitate the
extraction of the equipment on the guides and so increasing their life span. To level the table,
it is necessary to adjust the legs in height.
The attachment to the wall and to the floor will depend on the material from which they are
made. The fastening must be very firm because the insert has a weight of about 115 kg, for
this reason, the following configurations are recommended according to the material where
the table will be fixed:
Material
Type of attachment
FMS M8x60 Ø10
Massive (slab, stone)
Metallic
FIP M8x60 Ø10
Massive and non-massive (brick)
Chemical