12.3
TORCH AMP 500 DGT REGULATION
Connect the AMP 500 DGT torch as described in Phar. 9.4 to Page
17.
A
LED
Current
LED
Voltage
Push-Button
( SET - )
Push-Button
( + )
Fig. 13
GB
36
Digital
Display
Arc
V
LED
Arc lenght
LED
Wire speed
Push-Button
( SET + )
Push-Button
( - )
Torch
Switch
By using the torch AMP 500 DGT (Torch MIG/MAG with digit con-
trol) it is possible to carry out from the distance the regulation of the
following:
A
- CURRENT if LED
flickers.
V
- ARC VOLTAGE if LED
- WIRE SPEED if LED
Arc
- ARC LENGTH if LED
- N° JOB by pressing the Push-Button ( SET - ) until the display
reads
(all the LED are off).
The JOB should be memorized on the frontal panel of the gene-
rator.
- INDUCTANCE by pressing the Push-Button ( SET + ) until the
display reads
(all the LED are off).
To select the size to be regulated, press the Push-Buttons
( SET + ) or ( SET - ) and carry out the regulation with the Push-
Buttons ( + ) and ( - ). The display shows the regulated value. Each
regulation is seen on the frontal panel of the wire feeder and vice
versa.
NOTE: It not possible to carry out the regulation described above
during the welding. The display shows the real welding current.
If the programme is set on STD (STANDARD regulation) it is only
possibile to regulate: ARC VOLTAGE, WIRE SPEED and INDUC-
TANCE.
QUAD AC/DC SERIES