WATER: REQUIREMENTS FOR SUPPLIED WATER

Caution - Warning
The appliance must be supplied with drinking water having the characteristics
shown in the table.
Parameters to be checked
Pressure
Water fl ow rate (l/h)
pH
TDS
Hardness
Langelier index ( Recommended) (**)
Salt and metallic ion contenti
Requested
Recommended (**)
(*) The value refers to the amount of water needed for steam production inside the cooking chamber.
(**) Values diff erent from these parameters may cause corrosion if combined with wrong use and envi-
ronment.
Important
It is sole responsibility of the operator / purchaser / owner of this equipment to verify that
the supply water, treated or not upstream of the water connection , falls within the stand-
ard values published in this document. Failure to comply with these values may damage
the equipment and void the manufacturer's warranty of the damaged parts.

WATER CONNECTION

Caution - Warning
Make the connection in compliance with the relevant legal requirements, using appropri-
ate and recommended materials
Important
This appliance is to be installed to comply with the
applicable federal, state, or local plumbing codes
having jurisdiction.
Connect the mains line to the appliance's connection
pipe, fi tting a shut-off tap (B) to allow the water sup-
ply to be cut off when necessary.
3378750_GB_inst
Value
200÷400 kPa (2÷ 4 bar) (*)
9 l/h (BX 61) (*)
12 l/h (BX 101) (*)
17,5 l/h (BX82) (*)
17,5 l/h (BX122) (*)
7÷8.5
40÷150 ppm
3÷9°f (1,5÷5°d, 2.1÷6.3°e, 30÷90 ppm)
>0.5
Chlorine
<0,1 mg/l
Chlorides
< 10 mg/l
Sulphates
< 30 mg/l
Iron
< 0,1 mg/l
Copper
< 0,05 mg/l
Manganese
< 0,05 mg/l
B
- 9 -