Additional Toxic Sensors
Range
Sensor
(ppm)
Cl
2
Chlorine
0 - 10
ClO
2
Chlorine
0 - 1
dioxide
CO-HC
Carbon
0 - 10000 5
Monoxide
H
S-LC
2
Hydrogen
0 - 100
Sulfide
HCN
Hydrogen
0 - 30
cyanide
NH
3
Ammonia
0 - 100
NO
2
Nitrogen
0 - 20
dioxide (S 20)
NO
2
Nitrogen
0 - 50
dioxide (XCell)
NO
0 - 200
Nitric oxide
PH
3
Phosphine
0 - 5
SO
2
Sulfur dioxide
0 - 20
* Response time is for normal temperature range with sensor in position #3
Reproducibility
Resolu-
Normal temperature
tion (ppm)
range:
±0.2 ppm or 10 %
0.05
of reading,
whichever is greater
±0.1 ppm or 10 %
0.01
of reading,
whichever is greater
±5 ppm or 10 %
of reading,
whichever is greater
±0.2 ppm or 10 %
0.1
of reading,
whichever is greater
±1 ppm or 10 %
0.5
of reading,
whichever is greater
±2 ppm or 10 %
1
of reading,
whichever is greater
±2 ppm or 10 %
0.1
of reading,
whichever is greater
±1 ppm or 10 %
0.1
of reading,
whichever is greater
±5 ppm or 10 %
1
of reading,
whichever is greater
±0.2 ppm or 10 %
0.05
of reading,
whichever is greater
±2 ppm or 10 %
0.1
of reading,
whichever is greater
ALTAIR 5X/ALTAIR 5X IR
Technical Specifications
Extended temp. range:
±0.5 ppm or 20 %
of reading,
whichever is greater
±0.2 ppm or 20 %
of reading,
whichever is greater
±10 ppm or 20 %
of reading,
whichever is greater
±0.5 ppm or 20 %
of reading,
whichever is greater
±2 ppm or 20 %
of reading,
whichever is greater
±5 ppm or 20 %
of reading,
whichever is greater
±3 ppm or 20 %
of reading,
whichever is greater
±2 ppm or 20 %
of reading,
whichever is greater
±10 ppm or 20 %
of reading,
whichever is greater
±0.25 ppm or 20 %
of reading,
whichever is greater
±3 ppm or 20 %
of reading,
whichever is greater
Nominal
response*
t(90)< 30 s
t(90)< 2 min
t(90)< 15 s
t(90)< 15 s
t(90)< 30 s
t(90)< 40 s
t(90)< 40 s
t(90)< 15 s
t(90)< 40 s
US
t(90)< 30 s
t(90)< 20 s