MSA ALTAIR 5X Manual De Uso página 59

Detector de gases múltiples
Ocultar thumbs Ver también para ALTAIR 5X:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

ALTAIR 5X IR
Manufacturer:
Product:
EC-Type Examination Certificate:
Type of protection:
Performance
Gas
Marking:
Li-Ion
Special Conditions:
The model ALTAIR 5X IR shall be charged by Manufacturer's chargers only (0 - 45 °C) and opened
in a non-hazardous area.
When using the ALTAIR 5X or ALTAIR 5X IR in a hazardous area, the device should be worn or carried
on the body. Do not store the device in a hazardous location. This prevents the possibility of the device
building up an electrostatic charge.
The antenna used for activation of the internal RFID tag with the RF radiation power shall not exceed
6 W for Group I and 2 W for Group IIC.
In the event of a combustible sensor overrange, the device should be exposed to fresh air for a
minimum of 20 minutes. Following this, a Zero Calibration procedure should be performed.
The pressure range is 90 kPa to 120 kPa for gas CH
The warm-up time for oxygen is up to 180 sec.
The alarm set points are not applied for measuring oxygen inertisation and it shall be taken into
account.
Quality Assurance Notification:
Year of Manufacture:
Serial No.:
National Certification:
Performance:
Gas:
Capacitance:
Mine Safety Appliances Company, LLC
1000 Cranberry Woods Drive
Cranberry Township, PA 16066 USA
ALTAIR 5X IR
FTZU 09 ATEX 0006 X
EN 60079-0:2012, EN 60079-1:2014, EN 60079-7:2007
EN 60079-11:2007, EN 50303:2000, EN 60079-18:2009
EN 60079-29-1:2007, EN 50 104:2010, EN 50271:2010
measuring range 0-100 % LEL:
Methane, Hydrogen, Propane, Butane, Pentane
Oxygen: measuring range 0-25 Vol %, indication range 0 - 30 Vol %
I M1 Ex ia I Ma
II 2G Ex db e ia mb IIC T4 Gb
Ta = -40 °C to +50 °C
Um 6,7 V
IP 65
in range 0-100 % (v/v) for IR sensor.
4
0080
see Label
see Label
FTZU 09 E 0027
EN 45544-1: 1999
EN 45544-2: 1999
EN 45544-3: 1999
EN 50104 : 2010
CO: 0-2000 ppm
CO
: 0-10 % v/v
2
H
S: 0-200 ppm
2
Oxygen: measuring range 0-25 Vol %,
indication range 0-30 Vol %
ALTAIR 5X/ALTAIR 5X IR
Certification
US
59

Hide quick links:

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Altair 5x ir

Tabla de contenido