Gr.4 time-out
CAUSE
This alarm is triggered when
an extraction is made on group
4 through the P5 – 'continuous
pouring' button for more than
120 seconds.
EFFECT
Group is turned off; push DEL on
display to delete the alarm.
Steam time-out
CAUSE
This alarm is triggered when
steam is produced through the
MCS where milk temperature
probe does not reach 30°C
within 60 seconds.
EFFECT
Steam supply is locked; push
DEL on display to delete the
alarm.
Type "ABP" alarms
Steam boiler time-out
CAUSE
This alarm is triggered when the
steam boiler does not reach the
temperature of 40°C within 10
minutes of turning on.
EFFECT
Boiler heating up is locked; push
DEL on display to delete the
72
alarm.
Boiler probe interrupted
CAUSE
This alarm is triggered when
boiler temperature probe is out
of the range.
EFFECT
Boiler heating up is locked; push
DEL on display to delete the
alarm.
Boiler probe short circuit
This alarm is triggered when
boiler temperature probe is out
of the range.
EFFECT
Boiler heating up is locked; push
DEL on display to delete the
alarm.
Boiler high temperature
CAUSE
This alarm is triggered when
boiler temperature probe has
exceeded 127°C.
EFFECT
Boiler heating up is locked; push
DEL on display to delete the alarm.
Steam probe interrupted
CAUSE
This alarm is triggered when
MCS temperature probe is out
of the range.
EFFECT
MCS function is locked; push DEL
on display to delete the alarm.