Gr.2 probe interrupted
CAUSE
This alarm is triggered when
group 2 temperature probe is
out of the range.
EFFECT
Group 2 heating up is locked;
push DEL on display to delete
the alarm.
Gr.2 probe short circuit
CAUSE
This alarm is triggered when
group 2 temperature probe is
out of the range.
EFFECT
Group 2 heating up is locked;
push DEL on display to delete
the alarm.
Gr.2 high temp.
CAUSE
This alarm is triggered when
group 2 temperature exceeds
120°C.
EFFECT
Group 2 heating up is locked;
push DEL on display to delete
the alarm.
74
Gr.3 probe time-out
CAUSE
This alarm is triggered when
group 3 does not reach the tem-
perature of 50°C within 5 minu-
tes of turning on.
EFFECT
Group 3 heating up is locked;
push DEL on display to delete
the alarm.
Gr.3 probe interrupted
CAUSE
This alarm is triggered when
group 3 temperature probe is
out of the range.
EFFECT
Group 3 heating up is locked;
push DEL on display to delete
the alarm.
Gr.3 probe short circuit
CAUSE
This alarm is triggered when
group 3 temperature probe is
out of the range.
EFFECT
Group 3 heating up is locked;
push DEL on display to delete
the alarm.