3.2 Electrical data

Enclosure class
Insulation class
Supply cable
50 Hz:
Voltage [VAC]
Power consumption, P
[W]
1
60 Hz:
Voltage,
power consumption, P
[W]
1

3.3 Dimensions

See dimensions at the end of these instructions.

3.4 Approvals

Materials in contact with the pumped liquid have
been approved by the British Water Regulations
Advisory Scheme (WRAS) according to BS 6920 for
use in drinking water.
Other approvals: See pump nameplate.

4. Functions

4.1 Control panel

The MQ pump is operated entirely by means of the
control panel, see fig. 2. The control panel offers the
possibility of starting/stopping the pump. The pump
settings and operating condition are indicated by in-
dicator lights.
Fig. 2
6
1 x 110-120 V –10/+6%
1 x 220-240 V –10/+6%
MQ 3-25
MQ 3-35
IP 54
B
2 m H07RN-F with/without plug
1 x 220-240 V –10/+6%
600
850
800
550
850
MQ 3-45
1000
1000
1050