Select Pipe Configuration
1. Press <Left Arrow> key and then <Down Arrow> key to select [Pipe Config].
2. Press <Right Arrow> key.
3. Press <Up/Down Arrow> keys to select a configuration that approximates the conditions
4. Press <ENTER> key to save selection. The [Anomaly Diams] menu will appear.
5. Press <Right Arrow> key twice. =
6. Press <Right Arrow> and then the <Up/Down Arrow> keys to select number of pipe
7. Press <ENTER> key to save selection.
FST020 IP65 NEMA 4X Quick Start
Operating Instructions, 08/2014, A5E03086489-AJ
upstream of your sensor mounting location. (Refer to the definitions below.)
Use this menu cell to select the pipe configuration that most accurately represents the
upstream pipe condition.
Use this menu cell to enter the number of pipe diameters between the upstream
configuration and the sensor installation.
diameters.
3.2 Programming the Transmitter
will appear.