Siemens SITRANS F FST020 IP65 NEMA 4X Instrucciones De Servicio página 25

Caudalímetros ultrasónicos
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Table 3- 3
Sensor Size
A2
B3
C3
D3
E2
Chart based on pipe size (pipes other than steel)
Table 3- 4
Sensor Size
A1H
A2H
A3H
B1H
B2H
C1H
C2H
D1H
D2H
D4H
Chart based on pipe wall thickness (steel pipes only)
FST020 IP65 NEMA 4X Quick Start
Operating Instructions, 08/2014, A5E03086489-AJ
Universal Sensor Selection Chart
Order Code
Min.
B
12,7
C
19
D
51
E
203
F
254
High Precision Sensor Selection Chart
Order Code
Min.
G
0,64
H
1,02
J
1,52
K
2,03
L
3,05
M
4,06
N
5,84
P
8,13
Q
11,18
R
15,75
Outer Diameter Range
(mm)
Max.
50,8
127
305
610
6096
Pipe Wall (mm)
Max.
1,02
1,52
2,03
3,05
4,06
5,84
8,13
11,18
15,75
31,75
Connecting
3.2 Programming the Transmitter
Outer Diameter Range
(inches)
Min.
Max.
0.5
2
0.75
5
2
12
8
24
10
240
Pipe Wall (inches)
Min.
Max.
0.025
0.04
0.04
0.06
0.06
0.08
0.08
0.12
0.12
0.16
0.16
0.23
0.23
0.32
0.32
0.44
0.44
0.62
0.62
1.25
23

Publicidad

Tabla de contenido
loading

Tabla de contenido