Connecting
3.3 Installing the Sensor
2. Slide sensor into a Mounting Frame back end first aligning the angled edge of the sensor
with the angled edge of the Mounting Frame. Keep sensor from making contact with the
pipe until it butts up against the Mounting Frame stop. Push sensor down to mate with
pipe.
3. Tighten the sensor clamping screws to hold the sensor firmly in place. Repeat procedure
for the other sensor.
4. Proceed to Connecting Sensor Cables.
Connecting Sensor Cables
1. Observing the upstream/downstream orientation, attach the UP (upstream) and DOWN
(downstream) cables to the sensors and finger tighten.
2. Attach the other ends to the UP and DOWN terminals of the transmitter and finger
tighten.
3. Close top cover and tighten securing screws.
Figure 3-11
32
To Downstream Sensor
To Upstream Sensor
Connecting Sensor Cables to Transmitter