PROPRIETÀ DELL'ARIA - Rettifica della potenza in relazione alle proprietà dell'aria
Le potenze specificate presuppongono le seguenti proprietà dell'aria (conformemente alle norme ISO 3046):
Pressione dell'aria 1000 mbar (14.503 psi) (750 mm Hg)
Temperatura aria
25°C (77°F)
Umidità
60%, solo motori aspirati (l'umidità si dissolve nel calore del turbocompressore)
Se l'aria si scosta da questi valori, verificare i fattori di rettifica (in %) riportati nella tabella seguente.
Ricorrere a tali fattori nel "Calcolo della potenza del motore".
Nota: Qualora un impianto venga utilizzato ad altitudini e/o temperature eccedenti i valori standard sopra riportati, è necessario effettuare una riduzione della potenza per
la qualità "più leggera" dell'aria di aspirazione. La diminuzione di densità dell' aria influisce sul motore determinandone una riduzione delle prestazioni. Poichè la
combustione risulta incompleta, si produce fumo nero ed aumenta il consumo specifico di carburante. Inoltre è presente il rischio di fuori giri e di surriscaldamento
del turbocompressore. Per evitare ciò, la potenza deve essere ridotta conformemente a "Riduzione della potenza del motore".
PROPRIETES DE L'AIR - Correction de puissance due aux propriétés de l'air
Les puissances données sont calculées sur la base des propriétés de l'air suivantes (comme pour ISO 3046):
Pression de l'air
1000 mbar (14.503 psi) (750 mm Hg)
Température de l'air 25 °C (77°F)
Humidité
60%, moteurs DN seulement (l'humidité disparaît avec la chaleur dans le urbocompresseur)
Si l'air diffère de ses valeurs, vous trouverez les facteurs de correction (en %) adéquats dans les graphes ci-dessous.
Utilisez les facteurs de correction donnés dans "Calcul de la puissance du moteur".
Remarque:si le moteur est constamment utilisé à des altitudes et/ou des températures qui dépassent les valeurs standard de test (ci-dessus), il faut procéder à une réduction
de puissance à cause de la plus faible densité de l'air d'aspiration. La diminution de la densité de l'air influe sur le moteur en entrainant une baisse de ses
performances. Simultanément, la combustion est incomplète ce qui dégage une fumée noire et entraîne une consommation de combustible plus élevée. De plus,
ceci risque d'entraîner une reprise de régime trop élevée et d'endommager le turbocompresseur (surchauffe). Pour éviter ceci, réduisez la puissance en fonction
de "Réduction de puissance du moteur".
AIR PROPERTIES - Output correction due to air properties
Specified outputs presuppose the following air properties (as per ISO 3046):
Air pressure
1000 mbar (14.503 psi)
Air temperature
25 °C (77°F)
Humidity
60%, DN-engines only (humidity vanishes in the heat in the turbo-charged)
If the air deviates from these values, correction factors (in %) are found in the graphs below.
Use the correction factors in "Calculation of engine output".
Note! If an installation is permanently used at altitudes and/or temperatures exceeding the given test standard values (above), a reduction of the output must be made due
to the "thinner" intake air. Reduced air density will negatively affect engine performance. There is, furthermore, a risk of overrevving and overheating damage to the
turbocharger. To avoid this, the output must be reduced according to "Derating of engine".
LUFTEIGENSCHAFTEN - Leistungskorrektur durch Lufteigenschaften
Die Leistungsspezifikation setzt folgende Lufteigenschaften voraus (nach ISO 3046):
Luftdruck
1000 mbar (14.503 psi) (750 mm Hg)
Lufttemperatur
25 °C (77°F)
Luftfeuchtigkeit
60%, nur Ansaugmotoren (Feuchtigkeit wird durch die im Turbolader erzeugte Hitze getrocknet).
Bei Abweichung der Lufteigenschaften von diesen Werten sind in nebenstehenden Diagrammen Korrekturfaktoren (in %) angeführt.
Benutzen Sie die Korrekturfaktoren bei der "Berechnung der Motorleistung".
Merke! Bei permanenten Anwendungen auf einer Höhe bzw. bei Temperaturen über den Testdaten (oben) ist ein Leistungsrückgang durch die "dünnere" Einsaugluft zu
erwarten. Dünne Luft beeinträchtigt den Motor und steigert die Wärmebelastungen infolge höherer Verbrennungsdrücke und -Temperaturen. Die geringere Luftdichte
wirkt sich auf den Motor aus und führt zu einer Leistungsreduzierung. Außerdem besteht die Gefahr, den Turbolader durch Überdrehzahl und Überhitzung zu
beschädigen. Zum Schutz vor diesen Auswirkungen sollte die Leistung gemäß den Angaben "Leistungsreduzierung des Motors" gesenkt werden.
PROPIEDADES DEL AIRE - Factor de corrección del rendimiento debido a las propiedades del aire
Los datos de salida especificados presuponen las siguientes propiedades del aire (según la norma ISO 3046):
Presión del aire
1000 mbar (14.503 psi) (750 mm Hg)
Temperatura del aire 25 °C (77°F)
Humedad
60 %, sólo motores DN (la humedad desaparece con el calor del turbocompresor).
Si el aire se desvía de estos valores, pueden verse los factores de corrección (en %) en los gráficos que aquí se muestran. Utilice dichos factores en el cálculo del rendimiento
del motor.
Nota: Si una instalación se emplea de forma permanente en altitudes y/o temperaturas que exceden los valores estándar (antes mencionados), será preciso reducir los
datos de salida debido a la entrada de aire con mayor nivel de oxígeno. La disminuciòn de densidad del aire influye en el motor determinando la reducciòn de sus
prestaciones. Al mismo tiempo, la combustión es incompleta, lo que provoca la salida de humo negro y mayor consumo de combustible. Asimismo, existe el riesgo
de dañar el turbocompresor por exceso de revoluciones y sobrecalentamiento. Para evitar esta posibilidad, los datos de salida deben reducirse de acuerdo con la
"reducción de la potencia del motor".