Setting the ballistic curve
Start with step 1 if you have not previously opened the
menu control, or with step 3 if you have just set the
unit of measure and
is still flashing in the display.
bAll
1.
Press and hold the secondary button
•
appears.
EU.US
2.
Press the secondary button
•
is displayed.
bt
3.
Press the secondary button briefly (<2 s) 1 time.
• The display switches to the ballistic curves
bALL.
Press the main button 2.
4.
• The display switches to
5.
Select a ballistic curve by pressing the main
button repeatedly.
–
to
or
to US12, or
EU1
EU12
US1
–
if you wish to use a curve previously
CuSt
stored by the app
– Select
if you don't want to display an
OFF
impact setting shown on the distance display
(AbC, see p. 53 ff).
– under bt, menu item
data from a relevantly equipped Nielsen-Keller-
mann device (Kestrel Elite models) via
Bluetooth
or
®
1
(≥ 3 s).
1
briefly (≥3 s).
or
EU1
US1
if you wish to transfer
LAt
6.
Save your setting by briefly pressing the
secondary button.
• The saved setting is initially lit continuously for
4 s as confirmation, then the display changes
first to the zeroing distance setting (SId) and
then disappears.
Once a ballistic curve is set, the device will display the
range value for 2 s and then the calculated correction
value for 6 s after each distance measurement.
EN
49