Safety Directives; Limitations Of Processing; Processing Equipment - Stryker SYSTEM G Manual De Instrucciones

Ocultar thumbs Ver también para SYSTEM G:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 13
7300-001-700 Rev-B

Safety Directives

WARNINGS:
▪ Before processing this equipment, read and understand
the care instructions. Pay particular attention to safety
information.
▪ Only individuals trained and experienced in the
processing of reusable medical devices should process
this equipment.
▪ ALWAYS provide personal protective equipment (PPE)
for processing personnel according to the instructions
and safety data sheets (SDS) supplied with the
detergent. Wear PPE at all times during processing.
▪ DO NOT reuse, reprocess, or repackage a device that
is intended for single use only.
▪ A single use device may not withstand chemical,
chemical vapor, or high temperature sterilization
reprocessing.
▪ Design features may make cleaning difficult.
▪ Reuse may create a contamination risk and
compromise structural integrity resulting in
operational failure or fragmentation during use.
▪ Critical product information may be lost during
repackaging.
Failure to comply may lead to infection or cross
infection and result in patient and/or healthcare staff
injury.

Limitations of Processing

Repeated processing has a minimal effect on this
equipment. See the Inspection section for additional
guidance on evaluating device functionality.
www.stryker.com

Processing Equipment

WARNINGS:
▪ Use only Stryker-approved equipment, unless
otherwise specified.
▪ DO NOT modify any system component or accessory.
NOTE: For a complete list of components or ordering
information, contact your Stryker sales representative or
call Stryker customer service. See the Contact Information
section. Outside the US, contact your nearest Stryker
subsidiary.
The following equipment is required to process devices
per the instructions in this manual:
▪ Warm, filtered or deionized water (See the Water
section.)
▪ Prepared, specially formulated detergents (See the
Detergents section.)
▪ PPE as recommended by the detergent manufacturer
(minimum: overalls, gloves, face/eye shield)
▪ Soft, lint-free cloth
▪ Non-abrasive, soft, flexible, synthetic-bristle brushes
▪ Syringe
▪ Absorbent wipes
▪ Medical-grade compressed air, < 140 kPa
▪ Oven
▪ Sterilization wrap, grade 500 or higher
▪ Chemical indicators
▪ Steam sterilizer (autoclave)
▪ Ethylene Oxide (EO) sterilizer
The following optional equipment may be purchased to aid
in processing:
Description
STRYKER SYSTEM G Sterilization
Case, 1 Hand Piece
STRYKER SYSTEM G Sterilization
Case, 2 Hand Pieces
EN
REF
7302-120-000
7302-130-000
3

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

7302-120-0007302-130-000

Tabla de contenido