Disassembly and disposal

7
Maintenance
8012137.YCB8 | SICK
Subject to change without notice
LED indicator/fault pattern /
LED indicator/fault pattern
Yellow LED flashes (only brie‐
fly) /
Yellow LED flashes (only briefly)
Signal interruptions when ob‐
ject is detected /
Signal interruptions when ob‐
ject is detected
The sensor must be disposed of according to the applicable country-specific regulati‐
ons. Efforts should be made during the disposal process to recycle the constituent ma‐
terials (particularly precious metals).
SICK sensors are maintenance-free.
We recommend doing the following regularly:
Clean the external lens surfaces
Check the screw connections and plug-in connections
No modifications may be made to devices.
Subject to change without notice. Specified product properties and technical data are
not written guarantees.
DISASSEMBLY AND DISPOSAL
Cause /
Cause
Teach-in mode /
Teach-in mode
Depolarizing property of the
object surface (e.g., tape), re‐
flection /
Depolarizing property of the
object surface (e.g., tape), re‐
flection
Measures /
Measures
Readjust the sensitivity
(teach-in) / Reflector is not
suitable for the application in
question (we recommend only
using SICK reflectors) / Check
sensing range and adjust if
necessary; see graphic H. /
Distance between the sensor
and the reflector is too long
Check the teach-in mode /
Check the teach-in mode
Reduce sensitivity or change
the position of the sensor /
Reduce sensitivity or change
the position of the sensor