17
Technical Information
Optional Serial Port
Tab. 9
Bytes
1
2
3-6
7
8
9
10
When the Request is "I" (Status readings), the Answer will contain a
string of 2 characters with the following parameters:
Tab. 10
Bytes
LSB X
MSB X
2
When the Request is "J" (Numerical readings), the Answer will
contain a string of 5 characters with the following parameters:
224/262
Meaning
Speed adjust value (in KRPM)
Speed threshold
Run up time in seconds (long coded in 4 bytes)
Deat time (0 = NO 1 = YES)
Soft Start mode (0 = NO 1=YES)
Water cooling (0 = NO 1=YES)
CRC
Meaning
0000 = STOP
0001 = WAITING INTERLOCK
0010 = STARTING
X
0011 = NORMAL OPERATION
X
0100 = HIGH LOAD
X
0101 = " "
0110 = FAILURE
0111 = APPROACHING LOW SPEED
1
X
R2 status (0 = OFF 1 = ON)
X
R1 status (0 = OFF 1 = ON)
X
...
...
CRC