3.4 Electrical data for VGA-113

3.4.1 Servomotor with current input

Servomotor
Synchronous motor with limit switches
Current input
4 - 20 mA
Actuating time 0-100 %
ca.95 s (50 Hz), ca. 76 s (60 Hz)
Power consumption
3 VA
Degree of protection
IP55
Permissible ambient
0 °C to +50 °C
temperature
Type key
Voltage
VGA-113-XXX/A1, N
230 V (50/60 Hz)
VGA-113-XXX/B1, N
115 V (50/60 Hz)

3.4.2 Servomotor with feedback potentiometer

Servomotor
Synchronous motor with limit switches
Feedback potentiometer Single potentiometer
Actuating time 0-100 %
ca.95 s (50 Hz), ca. 76 s (60 Hz)
Power consumption
3 VA
Degree of protection
IP55
Permissible ambient
0 °C to +50 °C
temperature
Type key
Voltage
VGA-113-XXX/A2, N 230 V (50/60 Hz)
VGA-113-XXX/B2, N 115 V (50/60 Hz)

4. Installation

4.1 Transport and storage

Handle with care, don't throw!
Dry and cool storage place.

4.2 Unpacking

Observe when unpacking:
– No humidity should get into gas-leading parts!
– No foreign matter should get into gas-leading parts!
Mount as soon as possible after unpacking.

4.3 Typical installations

Nominal current
0.011 A
0.022 A
Nominal current
0.011 A
0.022 A
Fig. 15 Vacuum regulator and dosing regulator
Item
1
2
3
5
6

4.4 Mounting

4.4.1 Dosing regulator

Mount the dosing regulator to the wall.
4
2
3
Description
Vacuum regulator e.g. VGA-111 (with contact pressure
gauge)
Dosing regulator VGA-113
Injector
Remote display for container empty indication
Adsorption device
Warning
Observe the information, see chapter
chlorine
1
0
bar 16
5
2. Handling
15