6. INSTALL THE HOOD
Rest the back cavity of the hood on the wood mounting strip.
Hold the hood until it is completely secured to the wood mounting strip.
Secure hood to
wood strip with (4)
screws #8 - 3/4" (for
30" and 36" width
hoods) or (6) screws
(for 42" width and
wider hoods) provided
at locations shown.
Drill (2) 3/16" size
holes into the drywall
for wall anchors
through the existing
holes in the inside hood back in the locations shown. Then install the two wall
anchors and attach the hood to these anchors with the remaining #8 - 3/4" screws
and the (2) washers provided.
7. INSTALL TRANSITION TO ROUGH-IN PLATE
Model 423, 424, 427, 453, or 454
Attach transition (if required) to blower plate.
Use duct tape to make all joints secure and air-tight.
NOTE: Model P6 Single Blower Plate connects directly to 7" round ductwork,
without a transition.
The rough-in plate for all the exterior blower models connects directly to
10'' round ductwork without a transition.
HD0049
CAUTION
Top of hood (inside view)
Mounting Screw Locations
Back of hood (inside view)
Wall Anchor Locations
HD0047
- 6 -