Table 10: Diagnostic data appended to input data
Byte no.
Bit no.
Word 1
Bit 0
Bit 1
Bit 2
Bit 3
Bit 4
Bit 5
Bit 6
Bit 7
Bit 8
Bit 9
Bit 10
Bit 11
Bit 12
Bit 13
Bit 14
Bit 15
Word 2
Bit 0
Bit 1
Bit 2
Bit 3
Bit 4
Bit 5
Bit 6
Bit 7
Bit 8
Bit 9
Bit 10
Bit 11
Bit 12
Bit 13
Bit 14
Bit 15
Word 3
Bit 0
Bit 1
Bit 2
Bit 3
AVENTICS™ Modbus TCP | R412028202-BAL-001-AC | English
Meaning
Diagnostic type and
device
Actuator voltage UA <
Bus coupler diagnosis
21.6 V
Actuator voltage UA <
UA-OFF
Electronics power
supply UL < 18 V
Electronics power
supply UL < 10 V
Hardware error
Reserved
Reserved
Reserved
The backplane of the
valve zone issues a
warning.
The backplane of the
valve zone issues an
error.
The backplane of the
valve zone attempts a
re-initialization.
Reserved
The backplane of the
I/O zone issues a
warning.
The backplane of the
I/O zone issues an er-
ror.
The backplane of the
I/O zone attempts a
re-initialization.
Reserved
Group diagnosis,
Group diagnoses of
module 1
modules
Group diagnosis,
module 2
Group diagnosis,
module 3
Group diagnosis,
module 4
Group diagnosis,
module 5
Group diagnosis,
module 6
Group diagnosis,
module 7
Group diagnosis,
module 8
Group diagnosis,
module 9
Group diagnosis,
module 10
Group diagnosis,
module 11
Group diagnosis,
module 12
Group diagnosis,
module 13
Group diagnosis,
module 14
Group diagnosis,
module 15
Group diagnosis,
module 16
Group diagnosis,
Group diagnoses of
module 17
modules
Group diagnosis,
module 18
Group diagnosis,
module 19
Group diagnosis,
module 20
Byte no.
Bit no.
Bit 4
Bit 5
Bit 6
Bit 7
Bit 8
Bit 9
Bit 10
Bit 11
Bit 12
Bit 13
Bit 14
Bit 15
Word 4
Bit 0
Bit 1
Bit 2
Bit 3
Bit 4
Bit 5
Bit 6
Bit 7
Bit 8
Bit 9
Bit 10
Bit 11
Bit 12
Bit 13
Bit 14
Bit 15
The group diagnostic data of the modules can also be accessed cycli-
cally.
5.5.2 Reading out the bus coupler diagnostic data
You can find a description of the diagnostic data for the valve zone in
section g 6. Structure of the Valve Driver
The diagnostic data for the I/O zone is described in the system descrip-
tions of the individual I/O modules.
5.6 Extended Diagnostic Data of the I/O Modules
In addition to group diagnosis, some I/O modules can send extended diagnostic
data with a length of up to 4 bytes to the controller. The total data length can
thus be up to 5 bytes:
Byte 1 of the diagnostic data contains the group diagnosis information:
• Byte 1 = 0x00: No error has occurred.
• Byte 1 = 0x80: An error has occurred.
Bytes 2 to 5 contain the extended diagnostic data of the I/O modules.
The extended diagnostic data can be read out from Input Register 80 (50hex).
Meaning
Diagnostic type and
device
Group diagnosis,
module 21
Group diagnosis,
module 22
Group diagnosis,
module 23
Group diagnosis,
module 24
Group diagnosis,
module 25
Group diagnosis,
module 26
Group diagnosis,
module 27
Group diagnosis,
module 28
Group diagnosis,
module 29
Group diagnosis,
module 30
Group diagnosis,
module 31
Group diagnosis,
module 32
Group diagnosis,
Group diagnoses of
module 33
modules
Group diagnosis,
module 34
Group diagnosis,
module 35
Group diagnosis,
module 36
Group diagnosis,
module 37
Group diagnosis,
module 38
Group diagnosis,
module 39
Group diagnosis,
module 40
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Data.
34