PHYSICAL INSTALLATION
Environmental Requirements
NOTICE
Risk of damage to VFD, or malfunction can occur due to improper handling, in-
stallation, or environment.
Do not mount VFD on equipment with excessive vibration.
Install in a location where temperature is within the range of product rating.
Mount VFD vertically (top up) for proper heat dissipation.
Do not mount VFD in direct sunlight or near other heat sources.
Do not install in corrosive environments.
Install at least 18" (45.7 cm) above the ground.
Installation of non-approved screening may damage the drive and/or reduce output.
The drive is intended for operation in ambient temperatures from -13 °F to 122 °F
(-25 °C to 50°C).
The drive electronics are air-cooled. Allow at least 6 inches (15.24 cm) of clearance
around the unit for air flow.
S S p p e e c c i i a a l l C C o o n n s s i i d d e e r r a a t t i i o o n n s s f f o o r r O O u u t t d d o o o o r r U U s s e e
The drive is suitable for outdoor use with a NEMA 3R rating; however, the following
considerations should be made for outdoor installations:
Mount the drive on a wall or back plate that is at least 6 inches (15.24 cm) larg-
er than the outer dimensions of the enclosure to maintain the NEMA 3R rating.
Mount the unit vertically with the wiring end oriented downward, and properly
secure the cover (also applies to indoor installations).
Protect from hose-directed or sprayed water as well as blowing rain. NEMA 3R
enclosures are capable of withstanding downward-directed rain only. Failure to do so may result in drive failure.
Install away from direct sunlight or locations subject to extreme temperatures or humidity.
Use appropriate screening for the air inlet and outlet when installed in areas where insect or small animal intrusion is an is-
sue. Refer to
"Accessories" on page 59
Clean screens on a regular basis to ensure proper airflow.
for ordering information.