For applications with a large pressure tank, or if the system takes too long to stop, this mode can be
modified to be more aggressive. The system behavior should be monitored when adjusting these set-
tings to ensure proper operation.
Standard, Aggressive, or Off.
T T a a n n k k S S i i z z e e : : Use to refine system performance when using a standard pressure sensor. Select either:
Small Tank, Large Tank
S S t t e e a a d d y y F F l l o o w w : : Select either Normal Performance or Reduced performance.
Refer to
"Steady Flow Selection (DIP SW1 — Position 4)" on page
B B r r o o k k e e n n P P i i p p e e D D e e t t e e c c t t i i o o n n : : Use to enable or disable the feature, as well as adjust the length of time before
the fault occurs.
Refer to
"Broken Pipe Protection" on page
W W e e t t F F l l o o o o r r D D e e t t e e c c t t I I n n p p u u t t : : Controls how the controller will react when the Wet Sensor control terminal is
used.
Fault with High (default). This supports the Franklin Electric Moisture Sensor device.
Fault with Low. This can be used with other unpowered dry contact switched input devices.
Refer to
"Moisture Sensor" on page
A A u u x x i i l l i i a a r r y y I I n n p p u u t t : : Controls how the drive will react when the AUX INPUT control terminal is used.
Fault with High (default): In this setting, the drive output will stop when the external switch closes.
Fault with Low: In this setting, the drive output will stop when the external switch opens.
In both cases, F F a a u u l l t t F F 2 2 6 6 will be displayed on the monitor. When the switch moves to the opposite posi-
tion, the drive output will restart after 30 seconds.
Refer to
"Drive Control Using an External Device (Auxiliary Input)" on page 41
U U n n i i t t s s S S e e l l e e c c t t i i o o n n : : Select either kilowatts or horsepower.
A A v v a a i i l l a a b b l l e e F F i i r r m m w w a a r r e e
Provides the capability to download the latest drive firmware using a mobile device and then update the
SubDrive/MonoDrive Connect.
39.
37for more information.
FE Connect Mobile Application
35.
for more information.