P P u u m m p p a a n n d d M M o o t t o o r r S S e e t t t t i i n n g g s s
Enter the required settings based on the pump and motor nameplate information. Refer to
figuration" on page 31
for detailed information.
The FE Connect App adds settings for more precise motor control:
M M o o t t o o r r P P o o l l e e s s : : Select either a 2- or 4-Pole motor (surface applications).
M M o o t t o o r r O O v v e e r r l l o o a a d d C C u u r r r r e e n n t t : : Set the exact current rating of the motor, which will override the DIP switch
presets (surface applications).
M M i i n n i i m m u u m m a a n n d d M M a a x x i i m m u u m m O O u u t t p p u u t t F F r r e e q q u u e e n n c c y y : : Set an exact frequency range for more precise control
than the DIP switch presets.
P P r r e e s s s s u u r r e e C C o o n n t t r r o o l l
S S e e n n s s o o r r T T y y p p e e : : This parameter sets which type of pressure sensor is being used.
Switch – Use when connecting to a standard pressure sensor.
Transducer (PSI) – Use for a 4-20mA pressure transducer scaled to psi.
Transducer (bar) – Use for a 4-20mA pressure transducer scaled to bar.
T T r r a a n n s s d d u u c c e e r r R R a a n n g g e e : : Sets the range of the transducer connected to the drive, when using a pressure
transducer.
100 to 300 psi
Default = 100 psi
P P r r i i m m a a r r y y S S e e t t p p o o i i n n t t : : Sets the target pressure the drive will maintain, when using a pressure transducer.
5 psi to T T r r a a n n s s d d u u c c e e r r R R a a n n g g e e — 5
Default = 50 psi
D D r r a a w w d d o o w w n n : : Allows the drive to regulate to the Pressure Setpoint and remain off until pressure drops to
the C C u u t t I I n n S S e e t t p p o o i i n n t t .
Disabled/Enabled
C C u u t t I I n n S S e e t t p p o o i i n n t t : : Sets the low pressure limit before the drive restarts, when using the Drawdown
function.
5 psi to P P r r i i m m a a r r y y S S e e t t p p o o i i n n t t —1
Default = 40 psi
P P r r o o p p o o r r t t i i o o n n a a l l G G a a i i n n : : Determines transducer input sensitivity. A greater value provides more sensitivity.
However, if set too high, the system may create an output frequency oscillation.
I I n n t t e e g g r r a a t t i i o o n n T T i i m m e e : : Determines response time to transducer input. A greater value provides slower re-
sponse and may cause oscillation of output frequency.
COMMUNICATIONS
FE Connect Mobile Application
"Drive Con-
45