SPECIFICATIONS
SubDrive 30 Connect/SubDrive 50 Connect
SubDrive 30 Connect/SubDrive 50 Connect
NEMA 3R
Model
(indoor/outdoor)
Voltage
Phase In
Frequency
Input from
Current (max)
Power
Power Factor
Source
Power (idle)
Power (max)
Wire Gauge Size(s)
Voltage
Phase Out
Frequency Range
Output to
Motor
Current (max)
Wire Gauge Size(s)
Factory Preset
Pressure
Setting
Adjustment Range
Temperature (at 230
Operating
VAC input)
Conditions*
Relative Humidity
Temperature
Storage**
Shelf Life
Dimensions
and Weight NEMA 3R
* Operating temperature is specified at full output power when installed as recommended. Refer to
"Over Temperature Foldback" on page
** Shelf life can be extended for one year by powering the drive for 60 minutes with no load.
58
SubDrive 30
5870205403C
23 A
5 Watts
4.2 kW
Refer to
"Input (Power) Wire and Fuse Sizing" on page
Single-Phase (3–wire) OR Three-Phase
30-78 Hz: 1/2-rated pump (3-Phase)
30-70 Hz: 2/3 or 3/4-rated pump (3-Phase)
30-60 Hz: Matched pump (3-Phase)
30-63 Hz (Single-Phase Motors)
60-156Hz: 1/2, 2/3, or 3/4–rated pump
(MagForce)
60-120Hz: Matched pump (MagForce)
10.9 A (three-phase)
13.2 A (single-phase 3-wire)
Refer to
"Output (Motor) Wire Sizing" on page
Transducer: 5-95 psi (0.3-6.6 bar)
Pressure Sensor: 25-80 psi (1.7-5.5 bar)
–13 °F to 122 °F (–25 °C to 50 °C)
–13 °F to 149 °F (–25 °C to 65 °C)
9-3/4" x 19-3/4" x 5-1/4" : 26 lbs
(25 x 50 x 13 cm) : (11.8 kg)
38.
208/230 ± 10% VAC
Single-Phase
60/50 Hz
~ 0.95
272 VAC Maximum
30-78 Hz: 1/2-rated pump (3-Phase)
30-70 Hz: 2/3 or 3/4-rated pump (3-
Phase)
30-60 Hz: Matched pump (3-Phase)
30-63 Hz (Single-Phase Motors)
60-156Hz: 2/3 or 3/4-rated pump
(MagForce)
60-120Hz: Matched pump (MagForce)
17.8 A (three-phase)
17.0 A (single-phase 3-wire)
50 psi (3.4 bar)
20-95%, non-condensing
1.5 Years
9-1/8" x 15-3/8" x 11-1/2" : 31 lbs
(66 x 39 x 29 cm) : (14.1 kg)
SubDrive 50
5870205503C
36 A
7 Watts
7.2 kW
24.
24.