Under normal working conditions and to reach the maximum potential of
the machine, the operator needs a space equal to 2 m by 1.5 m as shown in
the figure on the side.
ELECTRICAL CONNECTION
The connection to the electrical network of the machine is made through the supplied power cable, which should be
carried out by specialized and authorized personnel, the relative socket of 16 / 32 A by 3-pole cable (F, N, T) for single-
phase and 4/5-pole versions (3F, T / 3F, N, T) for three-phase versions.
The electrical outlet must be easily accessible, and must not require any movement.
The distance between the machine and the socket must be such that it does not cause tension in the power cable, in
addition this cable must never be under the supports of the machine.
IMPORTANT
It is mandatory that the installation be equipped with earthing and a differential switch in accordance with the
applicable laws.
USE AND OPERATION
SAFETY
The machine is equipped with appropriate safety devices consisting of fixed guards, and sufficient distance between the
tank and the frame of the machine, with the aim of avoiding contact of parts of the human body (upper limbs) with the
tank. rotating during machining, to avoid any risk of dragging and crushing.
The Machine is equipped with the open bowl cover sensor, in order to avoid any contact of the human body parts (upper
limbs) with the moving parts during the machining phase, in order to eliminate any risk of dragging, d crushing and
abrasion.
DO NOT REMOVE GUARDS WHILE USING THE MACHINE.
THE MANUFACTURER DISCLAIMS ALL RESPONSIBILITY WHEN
REPORT TO ANY INDICATION ABOVE .
With reference to figure 8, the protections are:
I – lifting of the protective grid
L – device that allows raising or lowering the cover
(only on mixers with tilting head)
M,M1 – Check pin in top (when down, tilt head mixers
only)
N – device that allows extracting the bowl (only on
mixers with tilting head) 0 – Locking the disc in the
bowl (only on mixers with tilting head)
BORN
BY
6