Descargar Imprimir esta página

Wilo EMU TR 50-2 Serie Instrucciones De Instalación Y Funcionamiento página 315

Ocultar thumbs Ver también para EMU TR 50-2 Serie:

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 1144
8.2
Operator responsibilities
8.3
Shut-down
8.4
Removal
Installation and operating instructions Wilo-EMU TR/TRE 50-2 ... 120-1
Shut-down/dismantling
▪ Installation/dismantling: The technician must be trained in the use of the necessary
tools and fixation materials for the relevant construction site.
▪ Lifting work: A specialist suitably trained in the operation of lifting devices must carry
out lifting work. Evidence must be presented in accordance with BGV D8 or applicable
local regulations.
▪ Locally applicable accident prevention and safety regulations of trade associations.
▪ Observe regulations for working with heavy loads and under suspended loads.
▪ Provide the necessary protective equipment and make sure that the personnel wears it.
▪ Provide adequate aeration in closed rooms.
▪ Take immediate countermeasures if there is a build-up of toxic or suffocating gases!
The mixer is deactivated during decommissioning, but remains installed. This ensures
that the mixer is always ready for operation.
To protect the mixer from frost and ice, always immerse the mixer completely in
the fluid.
The fluid temperature must always be above +3 °C (+37 °F).
1. Switch off the mixer at the operating point.
2. Secure the operating point against being switched on again by unauthorised per-
sons (e.g. lock main switch).
▶ The mixer is decommissioned and can now be dismantled.
If the mixer remains installed after decommissioning, observe the following:
▪ Ensure that the aforementioned requirements are maintained for the complete period
of decommissioning. If these requirements cannot be guaranteed, dismantle the mixer
after decommissioning!
▪ For an extended period of decommissioning, carry out a 5‑minute function test at reg-
ular intervals (monthly to quarterly). CAUTION! A function test should only be carried
out under the applicable operating conditions. Never run the machine dry! Non-
compliance can lead to irreparable damage!
DANGER
Danger due to fluids hazardous to health during removal!
During removal, contact with fluids that are hazardous to health may occur. Observe
the following points:
• Wear protective equipment:
⇒ Closed safety goggles
⇒ Mouth protection
⇒ Protective gloves
• Immediately wipe up drips.
• Observe the specifications in the work regulations! The operator must make
sure that the personnel have received and read the work regulations!
DANGER
Danger from fluids hazardous to health!
Risk of fatal injury if the mixer is used in fluids hazardous to health.
• Decontaminate the mixer after dismantling and before carrying out any other
work.
• Observe the specifications provided by work regulations. The operator must
make sure that personnel have received and read work regulations.
en
315

Publicidad

loading