TOHATSU M 9.9D2 Manual Del Propietário página 57

Ocultar thumbs Ver también para M 9.9D2:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

.
1
1
2
1. Flushing attachment (option)
2. Water inlet
3. Sub-water inlet
ENOM00085-A
Flushing by test tank
ENOW00081-0
WARNING
Do not start engine without removing pro-
peller, or accidentally turning propeller
could cause personal injury.
ENOW00082-0
WARNING
Never start or operate the engine indoors
or in any space which is not well ventilated.
Exhaust gas contains carbon monoxide, a
colorless and odorless gas which can be
fatal if inhaled for any length of time.
ENOW00036-A
CAUTION
When the engine is started in the test tank,
to avoid over heating and water pump
damage, be sure the water level is at least
10 cm (4 in.) above the anti ventilation
plate.
INSPECTION AND MAINTENANCE
And be sure to remove the propeller, when
starting the engine in the test tank. (See
page 60)
3
3
2
ENOF01420-B
1. Test tank
2. Water
3. Over 10 cm (4 in.)
ENOM00950-0
Fuse replacement (For electrical
starter type)
ENOW00923-0
Before replacing a fuse, disconnect the
battery cable from the battery negative (-)
terminal. Failure to do so may cause a
short-circuit.
ENOW00924-0
Never use a fuse with a rating that exceeds
the specified rating as this could cause
serious damage to the electrical system.
If a blown fuse is detected, try to deter-
mine the cause for this and correct it. If the
cause for the problem is not corrected, the
fuse will likely blow again.
If the fuse continues to blow, request an
authorized Tohatsu dealer to inspect the
outboard motor.
1